Please use this identifier to cite or link to this item:
http://repositorio.unitau.br/jspui/handle/20.500.11874/1357
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Reis M.L.C.C. | pt_BR |
dc.contributor.author | Araújo M.C.C. | pt_BR |
dc.contributor.author | Souza M.S. | pt_BR |
dc.contributor.author | Santos R.R. | pt_BR |
dc.date.accessioned | 2019-09-11T20:51:31Z | - |
dc.date.available | 2019-09-11T20:51:31Z | - |
dc.date.issued | 2018 | - |
dc.citation.volume | 1065 | pt_BR |
dc.citation.issue | 7 | pt_BR |
dc.identifier.doi | 10.1088/1742-6596/1065/7/072034 | pt_BR |
dc.identifier.issn | 17426588 | - |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85057484359&doi=10.1088%2f1742-6596%2f1065%2f7%2f072034&partnerID=40&md5=fdf511e1112f8741ae7b7677aa86aab5 | - |
dc.identifier.uri | http://repositorio.unitau.br/jspui/handle/20.500.11874/1357 | - |
dc.description | 72034 | pt_BR |
dc.description.abstract | A test campaign to analyse the flow quality of the TA-2 subsonic wind tunnel is under progress. The measurand is the airflow speed. The velocity uniformity and the boundary layer velocity profile at the wind tunnel test section must be known because they impact on the model test results. The measured parameters are static pressure, total pressure, and static temperature. The estimated parameters are density and velocity. The least squares method is used for curve fitting. The uncertainties associated with the measured and estimated parameters are evaluated according to the recommendations of the Metre Convention. The results are presented in such a way as to help the wind tunnel community, including experimentalists and customers, to visualize and to quantify the airflow condition. Data reduction revealed that the airflow velocity decreases from the entrance to the centre of the test section. The boundary layer is thicker at the floor, in comparison with the lateral walls. © 2018 Institute of Physics Publishing. All rights reserved. | en |
dc.description.provenance | Made available in DSpace on 2019-09-11T20:51:31Z (GMT). No. of bitstreams: 0 Previous issue date: 2018 | en |
dc.language | Inglês | pt_BR |
dc.publisher | Institute of Physics Publishing | - |
dc.relation.ispartof | Journal of Physics: Conference Series | - |
dc.relation.haspart | 22nd World Congress of the International Measurement Confederation, IMEKO 2018 | - |
dc.rights | Acesso Aberto | pt_BR |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.source | Scopus | pt_BR |
dc.subject.other | Air | en |
dc.subject.other | Boundary layer flow | en |
dc.subject.other | Boundary layers | en |
dc.subject.other | Curve fitting | en |
dc.subject.other | Least squares approximations | en |
dc.subject.other | Parameter estimation | en |
dc.subject.other | Quality control | en |
dc.subject.other | Uncertainty analysis | en |
dc.subject.other | Velocity | en |
dc.subject.other | Air flow velocity | en |
dc.subject.other | Boundary layer velocity | en |
dc.subject.other | Estimated parameter | en |
dc.subject.other | Least squares methods | en |
dc.subject.other | Measured parameters | en |
dc.subject.other | Static temperature | en |
dc.subject.other | Subsonic wind tunnels | en |
dc.subject.other | Wind tunnel tests | en |
dc.subject.other | Wind tunnels | en |
dc.title | Flow quality analysis of the TA-2 wind tunnel | en |
dc.type | Trabalho apresentado em evento | pt_BR |
dc.description.affiliation | Reis, M.L.C.C., Instituto de Aeronáutica e Espaço, Pr. Mal. Eduardo Gomes 50CEP 12228904, Brazil, Instituto Tecnológico da Aeronáutica, Pr. Mal. Eduardo Gomes 50CEP 12228900, Brazil, Universidade de Taubaté, Rua Daniel Danelli s/nCEP 12060440, Brazil | - |
dc.description.affiliation | Araújo, M.C.C., Instituto Tecnológico da Aeronáutica, Pr. Mal. Eduardo Gomes 50CEP 12228900, Brazil | - |
dc.description.affiliation | Souza, M.S., Instituto de Aeronáutica e Espaço, Pr. Mal. Eduardo Gomes 50CEP 12228904, Brazil | - |
dc.description.affiliation | Santos, R.R., Universidade de Taubaté, Rua Daniel Danelli s/nCEP 12060440, Brazil | - |
dc.identifier.scopus | 2-s2.0-85057484359 | - |
dc.contributor.scopus | 7102676374 | pt_BR |
dc.contributor.scopus | 57197018043 | pt_BR |
dc.contributor.scopus | 57202835362 | pt_BR |
dc.contributor.scopus | 57207142595 | pt_BR |
Appears in Collections: | Trabalhos Apresentados em Eventos Artigos de Periódicos |
Files in This Item:
File | Size | Format | |
---|---|---|---|
2-s2.0-85057484359.pdf | 580.5 kB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License