Please use this identifier to cite or link to this item: http://repositorio.unitau.br/jspui/handle/20.500.11874/2267
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDiez J.S.V.pt_BR
dc.contributor.authorBrigagão V.C.pt_BR
dc.contributor.authorCunha L.G.pt_BR
dc.contributor.authorNeves, Ana Christina Claropt_BR
dc.contributor.authorSilva-Concílio, Laís Regiane dapt_BR
dc.date.accessioned2019-09-12T16:33:07Z-
dc.date.available2019-09-12T16:33:07Z-
dc.date.issued2012-
dc.citation.volume27pt_BR
dc.citation.issue5pt_BR
dc.citation.spage1055-
dc.citation.epage1060-
dc.identifier.issn8822786-
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84879283103&partnerID=40&md5=0947d3425b3bc39e38ed4c184ce130c7-
dc.identifier.urihttp://repositorio.unitau.br/jspui/handle/20.500.11874/2267-
dc.description.abstractPurpose: To evaluate the implant-abutment interface area and the abutment screw loosening value when diamondlike carbon (DLC)-coated or titanium screws were used before and after cyclic loading. Materials and Methods: Thirty-six implants were divided into four groups according to the type of connection (external hexagon [EH] or internal hexagon [IH]) and the type of abutment screw (with [EHD/IHD] or without [EHT/IHT] DLC coating). The implants were placed in epoxy resin-glass fiber composite, and crowns cast in a metal alloy were screwed to the implants. The implant-abutment interface was measured before (VG1) and after (VG2) cyclic loading. The removal torque values were recorded. Results: In groups with titanium screws, there was an increase in the implant-abutment interface area from VG1 to VG2, whereas in groups with DLC-coated screws, the interface area was reduced (EHT = 4.49%, IHT = 24.32%, EHD =-1.05%, IHD =-9.95%). In the IHT group only, the implant-abutment interface area showed a statistically significant difference between VG1 and VG2. The Pearson correlation indicated no significant differences among the studied factors, where r =-0.11 for EHT, 0.14 for EHD, 0.07 for IHT, and 0.43 for IHD. Conclusions: The implant-abutment interface areas in groups with an EH connection were larger than those in groups with an IH connection, regardless of the type of screws used. The screw loosening values decreased in all groups after cyclic loading. No correlation between the implant-abutment interface area and the screw loosening value was seen. © 2012 by Quintessence Publishing Co Inc.en
dc.description.provenanceMade available in DSpace on 2019-09-12T16:33:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2012en
dc.languageInglêspt_BR
dc.relation.ispartofInternational Journal of Oral and Maxillofacial Implants-
dc.rightsAcesso Restritopt_BR
dc.sourceScopuspt_BR
dc.subject.otherDental implantsen
dc.subject.otherImplant screwen
dc.subject.otherMarginal adaptationen
dc.subject.othercarbonen
dc.subject.otherdiamonden
dc.subject.otherepoxy resinen
dc.subject.othertitaniumen
dc.subject.otherarticleen
dc.subject.otherdental abutmenten
dc.subject.otherdental pinen
dc.subject.otherendodonticsen
dc.subject.otherhumanen
dc.subject.othertooth crownen
dc.subject.othertooth implanten
dc.subject.othertooth prosthesisen
dc.subject.othertorqueen
dc.subject.otherCarbonen
dc.subject.otherCrownsen
dc.subject.otherDental Abutmentsen
dc.subject.otherDental Implantsen
dc.subject.otherDental Marginal Adaptationen
dc.subject.otherDental Pinsen
dc.subject.otherDental Prosthesis Designen
dc.subject.otherDiamonden
dc.subject.otherEpoxy Resinsen
dc.subject.otherHumansen
dc.subject.otherTitaniumen
dc.subject.otherTorqueen
dc.titleInfluence of diamondlike carbon-coated screws on the implant-abutment interfaceen
dc.typeArtigo de Periódicopt_BR
dc.description.affiliationDiez, J.S.V., Department of Prosthodontics, University of Taubate, Taubate, São Paulo, Brazil-
dc.description.affiliationBrigagão, V.C., Department of Prosthodontics, University of Taubate, Taubate, São Paulo, Brazil-
dc.description.affiliationCunha, L.G., Dental Clinic Department, University of Bahia, Salvador, BA, Brazil-
dc.description.affiliationNeves, A.C.C., Department of Prosthodontics, University of Taubate, Taubate, SP, Brazil-
dc.description.affiliationDa Silva-Concílio, L.R., Department of Prosthodontics, University of Taubate, Taubate, SP, Brazil-
dc.identifier.scopus2-s2.0-84879283103-
dc.contributor.scopus55772083500pt_BR
dc.contributor.scopus22233859600pt_BR
dc.contributor.scopus54790562800pt_BR
dc.contributor.scopus25929472300pt_BR
dc.contributor.scopus8502637600pt_BR
Appears in Collections:Artigos de Periódicos

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.