Please use this identifier to cite or link to this item:
http://repositorio.unitau.br/jspui/handle/20.500.11874/6783
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Barchetta, Nayara Fernanda | pt_BR |
dc.contributor.author | Rosa, Evellyn Tainá Marques, 2001- | pt_BR |
dc.contributor.author | Okura, Carolina Sayuri Souza, 2001 | pt_BR |
dc.date.accessioned | 2024-01-23T19:01:58Z | - |
dc.date.available | 2024-01-23T19:01:58Z | - |
dc.date.issued | 2023 | pt_BR |
dc.identifier.uri | http://repositorio.unitau.br/jspui/handle/20.500.11874/6783 | - |
dc.description | Orientação: Profa. Dra. Nayara Fernanda Barchetta Villalta | pt_BR |
dc.description | Monografia (graduação) - Universidade de Taubaté, Departamento de Odontologia, Taubaté, 2023. | pt_BR |
dc.description.abstract | Resumo: O objetivo deste estudo foi avaliar possíveis alterações dimensionais na resina acrílica ativada quimicamente (RAAQ), que é utilizada para a confecção de guia cirúrgico para implante dentário, após a esterilização por autoclave. Foram produzidas dez amostras (N=10) de RAAQ e realizadas duas medições em cada amostra (diâmetro e espessura) utilizando um paquímetro digital. As medições foram feitas antes e após o processo de esterilização. As amostras foram esterilizadas em autoclave a 128°C por 1 hora e 30 minutos. Os resultados foram tabulados e analisados estatisticamente por meio de ANOVA um-fator e teste de Tukey (5%). Observou-se que não houve diferença estatisticamente significativa nos valores de diâmetro (p=0,787) e espessura (p=0,606), indicando a ausência de alterações significativas nas dimensões dos modelos após a esterilização. Pode-se concluir que a esterilização por autoclave é um métodoviável para guias cirúrgicos confeccionados em resina acrílica ativada quimicamente, uma vez que não compromete suas características dimensionais. | pt_BR |
dc.description.abstract | Abstract: The aim of this study was to assess potential dimensional changes in chemically activated acrylic resin (CAAR), used in the fabrication of surgical guides for dental implants, after autoclave sterilization. Ten samples (N=10) of CAAR were produced, and two measurements (diameter and thickness) were taken using a digital caliper on each sample. Measurements were conducted before and after the sterilization process. The samples were sterilized in an autoclave at 128°C for 1 hour and 30 minutes. The results were tabulated and statistically analyzed using one-way ANOVA and Tukey's test (5%). It was observed that there were no statistically significant differences in diameter values (p=0.787) or thickness values (p=0.606), indicating no significant alterations in the dimensions of the models following sterilization. It can be concluded that autoclave sterilization is a viable method for CAAR-based surgical guides as it does not compromise their dimensional characteristics. | pt_BR |
dc.description.provenance | Made available in DSpace on 2024-01-23T19:01:58Z (GMT). No. of bitstreams: 1 EvellynTainaMarquesRosa_CarolinaSayuriSouzaOkura..pdf: 715149 bytes, checksum: f9966bab9c2221cb1b7383fd8133ecaf (MD5) Previous issue date: 2023 | en |
dc.format.extent | 1 recurso online (27 f.) : digital, arquivo PDF. | pt_BR |
dc.format.mimetype | application/pdf | pt_BR |
dc.language | Português | pt_BR |
dc.relation.requires | Requisitos do sistema: Software para leitura de arquivo em PDF. | pt_BR |
dc.rights | Acesso Aberto | pt_BR |
dc.subject | Implantes dentários | pt_BR |
dc.subject | Autoclave | pt_BR |
dc.subject | Esterilização de instrumentos cirúrgicos | pt_BR |
dc.title | Esterilização de guia cirúrgico para implante dentário | pt_BR |
dc.type | Trabalho de Graduação | pt_BR |
dc.contributor.other | Assis, Afonso Celso Souza de | pt_BR |
dc.contributor.other | Chester, Leandro Notari, 1990- | pt_BR |
dc.contributor.other | Santos, Alexandre Cursino de Moura, 1971- | pt_BR |
dc.contributor.other | Universidade de Taubaté. Departamento de Odontologia | pt_BR |
Appears in Collections: | Odontologia - Trabalhos de Graduação |
Files in This Item:
File | Size | Format | |
---|---|---|---|
EvellynTainaMarquesRosa_CarolinaSayuriSouzaOkura..pdf | 698.39 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.